Zenith AS110024C Speaker Wire Southwire 55082415 Armored Cable Zenith AS105018C Speaker Wire
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Wire whip, 14/3 AWG. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Zenith AS105016C Speaker Wire Romex SIMpull 14/2NM-WGX25 Building Wire Romex SIMpull 14/2UF-W/GX25 Building Wire
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Zenith AS110018C Speaker Wire Armorlite 68579221 Type MC Armored Cable Armorlite 68580021 Type MC Armored Cable
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Zenith AS105014C Speaker Wire Romex SIMpull 12/2NM-WGX25 Building Wire Romex SIMpull 14/3NM-WGX25 Building Wire
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2UF-W/GX25 Building Wire Romex SIMpull 14/2NM-WGX50 Building Wire Southwire 22955952 THHN Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22957552 THHN Building Wire Southwire 22956752 THHN Building Wire Southwire 22959152 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22955951 THHN Building Wire Southwire 22956751 THHN Building Wire Southwire 22957551 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22959151 THHN Building Wire Southwire 22973236 THHN Building Wire Southwire 22974036 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22975736 THHN Building Wire Southwire 22977336 THHN Building Wire Romex SIMpull 14/2UF-WGX50 Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Armorlite 68579222 Type MC Armored Cable Armorlite 68583421 Type MC Armored Cable Romex SIMpull 10/2NM-WGX25 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3NM-WGX25 Building Wire Southwire 22964152 THHN Building Wire Southwire 22966652 THHN Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22968252 THHN Building Wire Southwire 22965852 THHN Building Wire Romex SIMpull 12/2NM-WGX50 Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/2NM-WGX100 Building Wire SIMpull 22964151 THHN Building Wire SIMpull 22965851 THHN Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
SIMpull 22966651 THHN Building Wire SIMpull 22968251 THHN Building Wire Armolite 68580022 Solid Metal Clad Cable
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Romex SIMpull 14/3NM-WGX50 Building Wire Romex SIMpull 12/2UF-WGX50 Building Wire Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Southwire 22973237 THHN Building Wire Southwire 22977337 THHN Building Wire Southwire 22974037 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22975737 THHN Building Wire Romex SIMpull 10/3NM-WGX25 Building Wire Romex SIMpull 14/3UF-WGX50 Type UF-B Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 14/2UF-WGX100 Building Wire Southwire 14BK-SOLX500 Solid Single Building Wire Southwire 14WHT-SOLX500 Solid Single Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 14RED-SOLX500 Solid Single Building Wire Southwire 14GRN-SOLX500 Solid Single Building Wire Southwire 14BLUE-SOLX500 Solid Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 14YEL-SOLX500 Building Wire Romex SIMpull 14/2NM-WGX250 Building Wire Armolite 68583422 Solid Metal Clad Cable
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
   
 