GE TGL1P Powermark Gold Ground Bar Kits, 7 Terminals
|
|
Cutler Hammer BRFPP Filler Plate, Plastic
|
|
GE THFILLER Rectangle Filler Plate, For Use with Knockouts
|
|
|
|
|
|
|
For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 - 8 AWG copper or 12 - 8 AWG aluminum terminals and 3 large holes for 14 - 4 AWG copper or 12 - 4 AWG aluminum terminals. UL Listed and ANSI Certified. 6.875" height x 2.875" width x 0.5" depth, .105 lb.
|
Plastic (snap-in) for type BR 1" space. May also be used with 400 amp and 600 amp load centers.
|
Covers circuit breaker knock outs that have been removed in error. Two 1" and two 1/2" plates.
|
|
GE TLK20CP Powermark Gold Ground Bar Kits, 20 Terminals
|
|
Square D QO70AN Auxiliary Neutral Lug Kit, For Use with Load Centers, 100 A
|
|
Square D QOFPCP Filler Plate, For Use with Load Centers
|
|
|
|
|
|
|
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL Listed. 2.875" height x .75" width x 6.875" depth, .07 lb.
|
Made for QO load centers. Field installed for number 12 - 2 Al or number 14 - 4 Cu wire. QO accessories can only be used with QO load centers.
|
Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified.
|
|
GE TGK24CP Powermark Gold Ground Bar Kits, 24 Terminals
|
|
Square D PK4GTACP Ground Bar Kits, Aluminum, 4 Terminals
|
|
Square D HOMFPCP Filler Plate, For Use with Load Centers
|
|
|
|
|
|
|
Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL Listed and ANSI Certified. 11" height x 3.5" width x 0.5" depth, .304 lb.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed.
|
Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified.
|
|
Square D HOM100AN Neutral Lug Kit, For Use with Load Centers, 100 A
|
|
Square D ACPCP Closing Plate, For Use With URTRS213B Metering Socket
|
|
Siemens EC38595 Closure Plate, For Use with Meter Sockets, 3/4 in
|
|
|
|
|
|
|
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 - 1/0 copper and aluminum wire. UL Listed, ANSI Certified.
|
Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. Use for A-size hub opening for Square D metering equipment. UL and CSA Listed.
|
Fits any meter socket application where a closure plate is needed.
|
|
Siemens ECLK2125 Sub-Feed Lug Kit, 2-Pole, 125 A
|
|
Load Center Cover Screws Pack6 - Case of 5
|
|
|
|
|
|
|
Sub feed lug kit. 125 amp. 2 pole. Lugs to sub feed to another panel.
|
Fit many types of service entrance devices and load center covers. Use them to replace lost or damaged screws.
|
|